Axis - 976 Leak tester is a single station leak detection system and specially manufacturing for detecting leaks at closed component low pressure leak detection system. Pneumatic System operating cycle minimum 1,00,00,000 cycles, user friendly operating system. High accuracy differential pressure sensors are using 0.07% of FS at ±500pa, ±1000pa, ±2500pa, ±5000pa.
Differential pressure loss measurement for closed component: The procedure is based on comparison of the pressures within the test part volume and within a reference volume respect of pre-filling reservoir.
Fast 24bit A/D converter Real-Time processing of the measurement signal.
Testing pressure range pressure sensor: -1-0bar, 0-0.1bar, 0-1bar, 0-7bar
Measuring range differential pressure sensor: ±500pa,±1000pa, ±2500pa, ±5000pa
Mechanical or Electronic regulator range -1-0bar, 0-1bar, 0-7bar
Upto 32 programs.
4" colour touch display.
Calibration leak port.
Auto zero calibration.
Data logging standard USB port.
Up to 60,000 data storage.
Unit: pa, pa/s, mbar, psi, bar, kpa and customized.
Unit for flow: ccm, sccm, ml/min, l/min, l/hr
Differential pressure leak rate method
Differential pressure leak standard
Rs 232 communication data storage
IO connector
10 inputs and 3 outputs with up to 5 programming bits
Expandable download USB port
Firmware updating port
Options: Ethernet/IP, profinet, printer and scanner
Dimensions: (WxHxD) 230x300x400mm
Weight: 13kg
230VAC/50Hz
Operating temperature: 10°C - 45°C
Clean, dry, non-corrosive gases
Test pressure: -1-0bar, 0-1bar, 0-7bar